Thermocouple Type K
- Temperature range: -100 °C to +1.100 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere
- Wire type: Silicone, Tmax: +180 °C, continuous
Description
Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point comes insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. The connection lead permits simple routing up to the measured-data acquisition. Options are available for the probe diameter and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.).
Technical data
- Sheathing thermocouple pairing: Type K
- Limiting deviation:Cl. 1 as per DIN EN 60584-1: 2014-07
- Sheathing material: Inconel600
- Measuring point:hot junction insulated
- Probe diameter: 1.0–3.0 mm
- Element length: 5–150 mm
- Thread: M5 / M6 / M8 / M8x1 / G1/4″
- Conductor: Silicone
- Conductor: Strand, 2x 0.22 mm²
- Wire length: 500–5,000 mm
- Connection: Selection
Discount on large quantities on request