Use:
Terminal rails enable the easy connection of thermocouples or resistance thermometer measurement circuits in junction boxes or on the rear side of devices.
Mechanical design:
- Core material of fibreglass-filled nylon
- Insulators between the contacts prevent short-circuits.
- Screw connections for easy installation.
- Available in a wide range of thermo-pairings.
- Dimensions suitable for the use of cable-shoes A-20.131-(…) and A-20.132-(…).
Temperature load:
- Max. +200 °C.
Conductor diameter:
- Reliable connection from 0.2 to 3.0 mm.
Available types:
- online available: Type K, J, E, N, T, U, R/S
Designation:
- The housing colour is black and the terminal bridges are labelled with the material.
Circuits | Dimension A (mm) | Dimension B (mm) |
---|---|---|
1 | 41 | 33 |
2 | 63 | 55 |
3 | 86 | 78 |
4 | 108 | 100 |
5 | 130 | 122 |
6 | 152 | 144 |
8 | 197 | 189 |
10 | 241 | 233 |
Discount on large quantities on request